Sabtu, 10 Februari 2018

Sponsored Links

Emergency oxygen system deployed after Cabin pressurization ...
src: i.ytimg.com

Aircraft emergency oxygen systems are emergency equipment fitted to pressurized commercial aircraft, intended for use when the cabin pressurisation system has failed and the cabin altitude has climbed above a safe level. It consists of a number of individual yellow oxygen masks stored in compartments near passenger seats and near areas like lavatories and galleys, and an oxygen source, like a centralized gaseous cylinder or decentralized chemical oxygen generator.


Video Emergency oxygen system



Use

Most commercial aircraft that operate at high flight altitudes are pressurized at a maximum cabin altitude of approximately 8,000 feet. On most pressurized aircraft, if cabin pressurization is lost when the cabin altitude is above 14,000 feet, compartments containing the oxygen masks will open automatically, either above or in front of the passenger and crew seats, and the oxygen masks will drop down in front of the passenger. Oxygen masks may also drop on extremely rough landings or during severe turbulence if the oxygen mask panel becomes loose. Rows of seats typically have an extra mask (i.e. 3 seats, 4 masks), in case someone has an infant in their lap, or someone in the aisle needs to grab one.

An oxygen mask consists of a yellow, soft, silicone facial cup with white elastic bands for securing the mask to the passenger's face. This band is adjustable by pulling two ends looped through the facial cup. The mask may also have a concentrator or re-breather bag that may or may not inflate depending on the cabin altitude, which has (in some instances) made passengers nervous the mask was not providing adequate oxygen, causing some to remove them, who thereby suffered hypoxia. All airlines now make a point in the safety video or demonstration to point out that the bag may not inflate. The bag is attached to a tube, connected to the oxygen source in the compartment, allowing for it to drop down and hang in front of the passengers. To operate on all aircraft except the L-1011, they must be pulled sharply toward the passenger who needs it to un-clip the flow pin and start the process of transporting the oxygen to the passenger. Passenger oxygen masks cannot deliver enough oxygen for sustained periods at high altitudes. This is why the flight crew needs to place the aircraft in a controlled emergency descent to a lower altitude where it is possible to breathe without emergency oxygen. While the masks are being used, passengers are not allowed to leave their seat for any reason until it is safe to breathe without the emergency oxygen. If there is a fire on board the aircraft, masks are not deployed, as the production of oxygen may further fuel the fire.

Aircraft safety cards and in-flight safety demonstrations shown at the beginning of each flight explain the location and use of oxygen masks.

Some aircraft, such as the SAAB Series Aircraft and the 1900D, have a mask system where either a mask is stored under the seat or is distributed by the cabin attendant. These masks are removed from packaging and plugged into the socket for oxygen supply.


Maps Emergency oxygen system



Mechanism

There are two systems that are typically found on aircraft:

  • A chemical oxygen generator system connected to all masks in the compartment. Pulling down on one oxygen mask removes the firing pin of the generator igniting a mixture of sodium chlorate and iron powder, opening the oxygen supply for all the masks in the compartment. Oxygen production cannot be shut off once a mask is pulled, and oxygen production typically lasts at least 15 minutes, sufficient for the plane to descend to a safe altitude for breathing without supplemental oxygen. During the production of oxygen, the generator becomes extremely hot and should not be touched. A burning smell may be noted and cause alarm among passengers, but this smell is a normal part of the chemical reaction. This system can be found on the MD-80 aircraft, whose system is also unique in the fact that the face masks are clipped to the inside of the compartment door and do not drop out and hang, by the oxygen tube, in front of the passengers. "For any aircraft which carries more than a very few passengers, the weight, complexity and maintenance issues associated with a compressed gas system would be prohibitive. As a consequence, the industry relies on chemical oxygen generators."
  • A gaseous manifold system, which connects all oxygen masks to a central oxygen supply, usually in the cargo hold area. Pulling down on one oxygen mask starts the oxygen supply for that mask only. The entire system can usually be reset in the cockpit or in some other location in the aircraft.

Pilot emergency oxygen mask deployment demonstration on MPS Boeing ...
src: i.ytimg.com


References

Source of the article : Wikipedia

Comments
0 Comments